Product description
The flow table is used to determine the flow of freshly mixed mortar, e. g. the DESOI AnchorNox® dry mortar. The flow gives information about the consistency of the fresh mortar. Both, falling below and exceeding the specified flow, will impair the quality of the cured mortar.
Procedure
Procedure
• Mix the injection mortar according to manufacturersÉ instructions
• Place the cone centrally on the flow table
• Use the funnel to fill in the fresh mortar up to the top edge of the cone, remove the funnel
• Lift the cone vertically
• After about 1 minute, the flow should range between 270 mm and 300 mm